SOM CODE : D341/14 Starling’s Miniature ‘Ideal’ Ventilator The Harvard Apparatus Starling ‘Ideal’ ventilator features negligible dead space, low noise, low wear and high reliability. The rate is indicated on a LED display. Both the rate and stroke can be changed while the ventilator is running. The fine pitch of the stroke control allows the stroke to be accurately set and the actual stroke is clearly displayed on a static pointer scale, not on the side of the piston, or moving scale. Three different sizes are available: 0.25 to 2.5 ml, 1.0 to 10 ml and 3.0 to 30 ml. All air drawn into the pump is expelled on each stroke. The negligible dead space feature ensures that the piston reaches the end of the cylinder at the top of every stroke. The speed of the motor is continuously monitored and regulated to maintain a constant stroke rate. The precision-machined valve assembly has four ports which provide maximum air channeling flexibility. The input may be room air or non-explosive gas mixtures. The exhaust air can be partially or completely recycled, or collected for analysis. The Harvard Apparatus Starling ‘Ideal’ ventilator is designed to generate minimal electro-radiated noise and meet the stringent EMC CIS-B regulations for radiated noise, as well as other current CE directives. Stroke volumes of 0 to 2.5, 0 to 10 and 0 to 30 ml • LED digital readout of rate and volume • Extremely quiet operation • Electromagnetically quiet (meets EMC-CIS-B regulation) • Rate and stroke adjustable during ventilation Specifications
|
|
||||||||||||||||
|
|
|||||||||||||||||
|
SOM CODE : D315/25 Model : 683 COMPANY : HARVARD, ENGLAND. VENTILATOR RODENT 683
Model 683 for small animals
from 250 g to 10 kg (22 lb) e.g. rats, hamsters, rabbits, cats, monkeys,
small dogs, etc. The Model 683 Small Animal
Ventilator comes standard with two piston and cylinder assemblies. The
smaller piston (which comes installed) allows tidal volumes to be set from
0.5 to 5.0 cc in 0.5 cc increments and the larger cylinder allows tidal
volumes of 3.0 to 30 cc in 0.3 cc increments. Setting the cylinder stroke
between gradations it is possible to achieve finer resolution in tidal
volume settings.
|
|
||||||||||||||||
|
|
|||||||||||||||||
|
SOM CODE : D97/1
Model : 6025 COMPANY : UGO BASILE,ITALY.
CAT/RABBIT VENTILATOR It consists of a
variable-speed geared motor linked by a novel variable stroke mechanism to
an interchangeable cylinder/piston assembly (50 or 100 ml).
|
|||||||||||||||||
|
Specifications
|
|
||||||||||||||||
|
|
|||||||||||||||||
COMPANY : HARVARD, ENGLAND. CANINE VENTILATION/ANESTHESIA MASKS. This masks provide a convenient way of providing artificial ventilation or administration of anesthetic gases to dogs. They are constructed of rugged transparent polycorbonate.One end has standard 15mm (3/5 in) taper for connection to anesthesia tubing. while the other end has a soft flexible rubber diaphragm that molds itself to the contours of a dogs snout.
|
|
||||||||||||||||
|
|
|||||||||||||||||
| Note : Please mention the product " SOM CODE " while making request for quotation and send it to dabab@somatco.com. | |||||||||||||||||
|
|
|||||||||||||||||
|
Copyright
© Saudi (Overseas) Marketing And Trading Company -2010 |
|||||||||||||||||