SOMATCO Supplies  Oxygen Concentrators, Oxygen Cylinders, Nebulizers, Humidifiers, Microscopes,  Laboratory Boiling Glasswares,  Laboratory Blown & pressed Glasswares,  Laboratory Bottles, Volumetric Glasswares,  Laboratory apparatus, Laboratory Coats, Hospital Electric Beds, Hospital Manual Beds, Dental Unit, Ovens, Incubators, Centrifuges, Balances, Thermometers, Shakers, Skeleton Models, Digital BP Meters, Mercury BP Meters, Wheel Chairs, Stethoscopes, Chemicals, Stirrers, Stirring Motors, Suction  Aspirators, Digital Autoclaves, Amplitron Thermal Cycler, Opthalmoscopes, Oscilloscopes, Otoscopes, Oxygen Regulators, Ph meters, Projectors, Radioactive Source Kit, Refrigerators.

شركة سوماتكو ترحب بكم  ويسرها خدمتكم يتوفر لدينا اجهزة توليد اكسجين ، اجهزة انعاش للربو ، مرطب للجو حار وبارد ، سماعات طبيب ، بالطو طبيب ، جهاز كشف الاذن ، جهاز كشف قاع العين ،جهاز قياس الضغط زئبقي والكتروني ، فرن تعقيم ، حاضنه الكترونيه ،سنترفيوج ، ميكرسكوب بجميع الانواع ، زجاجيات للمختبر ، كيماويات ، خرائط تعليميه ، كراسي معوقين ، اسره مرضي كهربائيه ويدويه ، موازين حساسه ، ورق ترشيح ، ادوات جراحيه ، ثلاجة لحفظ الدم ، مراتب طبيه والكثير من التجهيزات الطبيه والعلميه والمخبريه


SOM CODE : 395
Model : OS-22600
COMPANY : SUN EQUIPMENT, USA

OSCILLOSCOPE 60Mhz

 

Brouchure 

CRT
Type: Rectangular with integral graticule
Display Area: 8 x 10 div (1 div = 1 cm)
Accelerating Voltage: 12kV
Phosphor: P31

Vertical Amplifiers ( CH1 and CH2)

Sensitivity: 5 mV/div to 5 V/div (X1 mode)
5 mV/div to 5 V/div (X1 mode) 1mV/div to 1V/div (X5 mode)
1-2-5 sequence, 10 step attenuator. Vernier control provides fully adjustable attenuation between steps.
Accuracy: +3% (X1 mode)
+5% (X1 mode)
Input Resistance: 1MW + 2%
Input Capacitance: 25 pF + 10 pF
Frequency Response: 5 mV to 5 V/div (CAL): DC to 60 MHz (-3 dB)
1 mV (CAL): DC to 20 MHz (-3 dB)
Rise Time: Approximately 5.8 ns
Operating Modes: CH1: CH1 single trace
CH2: CH2 single trace
ALT: dual trace, alternating
CHOP: dual trace, chopped
ADD: algebraic sum of CH1 + CH2
Polarity Reversal (Invert): CH2 only
Maximum Input Voltage: 400V dc + ac peak
Maximum Undistorted Amplitude: DC-to-60MHz: 4 divisions
DC-to-40MHz: 8 divisions

 

Horizontal Amplifier (CH1)

X-Y Mode: Switch selectable using X-Y switch,
CH1: X Axis, Ch2: Y-axis
Sensitivity: Same as vertical channel 2
Accuracy: Y-Axis: ±3 %, X-Axis: ±6%
Input Impedance: Same as vertical channel 2
Frequency Response: DC to 1MHz typical (-3 dB)
X-Y Phase Difference: Approximately 3° at 50 kHz
Maximum Input Voltage: Same as vertical channel 2

 


SOM CODE : D54/155.
Model : HVP-22015
COMPANY : SUN EQUIPMENT, USA

High Voltage probe

Specifications:

Model HVP-22015
Input Impedance 100MW +/_ 1%
Max. Test Voltage 1000 : 1
Safety Application EN61010 UL3111-1 TUV/GS

IE 1010 CAT II Pollution 2

Accuracy DC: ± 1.5% to 10KV,
       ± 2.5% to 15KV
Temperature Coefficient < 200 PPM / °C
Operating Temperature 0°C ~ 50°C
Storage Temperature -20°C ~ 70°C
Ground Lead Length 3 ft
Output Cable Length 3.3 ft
Application Oscilloscope/DMM (optional)
Output Division 1V / 1KV
Dimensions 340 mm x 75Ø
Weight 300 g

 

Brouchure 


Note : Please mention the product "SOM CODE" while making request.