Model :
HI98129
|
SOM CODE : 1462/129  Model :
HI98129 COMPANY : HANNA, ITALY.
pH / EC / 0C
Pocket Tester. The
new waterproof HI98129 tester from Hanna are designed for high
accuracy pH, EC/TDS and temperature measurements. No more
switching meters to measure the
pH and then the EC or TDS of a solution. This tester also have a
stability indicator and hold feature to prompt the user when to
take the reading and freeze the display for easy and accurate
recording.
- Rugged, Floating Waterproof Casing.
- Temperature in 0C and 0F.
- Measurement Stability Indicator.
- Replaceable pH Electrode Featuring and Extendable Junction.
- Automatic pH calibration at standard as well as NIST Buffer
Sets.
- Automatic Temperature Compensation (ATC).
- Adjustable Temperature Coefficient Factor.
Specification:
| SOM
CODE | 1462/129 |
| Model | HI98129 |
| Range | 0.00
to 14.00 pH; 0.0 to 60.00C;
0 to 3999 mS/cm (EC); 0 to 2000 ppm. (TDS) |
| Resolution | 0.01pH;
0.10C; 1mS/cm; 1 ppm. |
| Accuracy | +
0.05pH;
+ 0.50C; + 2% Full Scale (EC/TDS) |
| Typical EMC
Deviation | +
0.02 pH; + 10C; + 2% Full Scale
(EC/TDS) |
Temperature Compensation | pH
: Automatic |
| Auto
Shut-off | After
8 minutes |
| Battery
Life/Type | 100
hours approx. continuous use/4 x 1.5V |
| Dimensions | 163
x 40 x 26 mm |
| Weight | 85
g. |
|
|
SOM CODE : 1462/301  Model :
pH301 COMPANY : HANNA, ITALY.
GLP
Bench pH/mV/Ion/0C Meter. The
pH calibration can be performed at 1, 2 or 3 points with 6
memorized pH values.
The opto-isolated RS232 is bi-directional, so that the user can
operate the meter from the computer key-board. The pH 301
logging function can be used in the pH, mV and ISE modes. The
logging interval is user-selectable. The memory is capable of
retaining up to 99 different lots of up to 8000 samples.
|
|
|
| SOM
CODE | 1462/301 |
| Model | pH
301 |
| Range | pH
/ 0C | -1.999
to 19.999 pH; -9.9 to 120.00C; |
| mV/ppm | +1999.9
mV; 0.001 to 19999 |
| Resolution | pH/ 0C | 0.01
& 0.001 pH; 0.10C |
| mV/ppm | 0.1
mV; 0.001;0.01; 0.1; 1 |
| Accuracy | pH/ 0C | +
0.002 pH; +0.50C |
| mV/ppm | +0.1
mV ; +1% F.S. |
| Typical EMC Deviation | +
0.01 pH; +0.50C;+0.3 mV; +1%
F.S. |
| pH Calibration | 1,2 or
3 points with 6 memorized buffers. |
| Temperature Compensation | Automatic
or manual from -9.9 to 1200C |
| Electrode | HI
1131B |
| Temperature
probe | HI7669/2W
with 1 m cable. |
| Power
supply | 12VDC
adapter |
| Dimensions | 280
x 200 x 75 mm |
| Weight | 1.3
Kg. |
|
|
SOM CODE : 1462/302 Model :
pH302+HI76405 COMPANY : HANNA, ITALY.
pH/mV/DC PRINTING METER
WITH ELECTRODE. The
pH 302 fulfills the needs of general purpose and analytical
laboratories for a single instrument to
measure pH, millivolt (mV), Oxidation Reduction Potential
(ORP), plus specific ions (ISE).
The oversized display is easy
to read and present step-by-step guidance for
calibration.
Instructions are also provide on the display to correct
calibration errors and guarantees optimal performance
while performing your measurements. Advance memory features also
enable you to recall calibration data to
comply with Good Laboratory Practices (GLP) protocols.
Programmable
Functions :
- Sampling
cycle - set the sample number, time and date.
- Custom calibration - calibrate the meter using nonstandard
buffer values
- GLP Compliance - prints calibration data with date, time, pH
offset and slope
- Time Study 1 - log and print pH, mV, and temperature to a
pre-set interval.
- Time Study 2 - log and print pH, mV, and temperature to a
pre-set parameter.
- Alarms - set upper and lower pH or mV limits
- International - choice different languages for printed data.
- ISE - print the ion concentration for pH values.
- Connectivity - sets up communication with your computer.
|
|

Model : pH302
|
| SOM
CODE | 1462/302 |
| Model | pH
302 |
| Range | pH | 0.00
to 14.00 |
| mV | +399.9
(ISE) ; +1999 (ORP) |
| oC | -9.9
to 120.0 |
| Resolution | pH/ 0C | 0.01pH
& 0.10C |
| mV | 0.1(ISE)
; 1(ORP) |
| Accuracy | pH/ 0C | +
0.01 pH; +0.50C |
| mV | +0.3
(ISE); +1(ORP) |
| Typical EMC Deviation | +
0.01 pH; +0.50C;+0.3 mV; +1%
. |
| pH Calibration | 1or
2 points with 3 memorized buffers. |
| Temperature Compensation | Automatic
or manual from -9.9 to 1200C |
| Electrode | HI
1131B combination, glass body, refillable,
BNC connector (included) |
| Temperature
probe | HI7669/2W,
thermistor type with 1 m cable. |
| Input
Impedance | 1012
Ohm |
| Inputs | BNC/Reference/ATC |
| Output | Bi-Directional
RS232 opto-isolated |
| Power
supply | 12VDC
adapter |
| Environment | 0
to 500C; RH 95% |
| Dimensions | 280
x 200 x 75 mm |
| Weight | 1.3
Kg. |
|
|
|
SOM CODE : 1462/211
Model :
pH211 COMPANY : HANNA, ITALY.
pH/mV
Bench Meter With Electrode, Probe & Solution.
The
new pH211 have been designed to be simple without
sacrificing accuracy. meters measures the pH from 0 to 14 and
temperature from 0 to 100 with 0.01 pH and 0.50C
accuracy. The pH211 can also measures mV in two ranges of +399.9
and +1999 mV in conjunction with ISE's and ORP electrodes.
The large display shows pH or mV and temperature at same time. |
Specifications :
| SOM
CODE | 1462/211 | | Model | pH
211 | | Range | pH
/ 0C | 0.00 to
14.0 pH; 0.0 to100.00C; |
| mV | +399.9
mV (ISE); +1999 mV (ORP) |
| Resolution | pH
/ 0C | 0.01
pH; 0.10C |
| mV | 0.1
mV (ISE); 1 mV (ORP) |
| Accuracy | pH
/ 0C | +
0.01 pH; +0.50C |
| mV | +0.2
mV (ISE); +1 mV (ORP) |
| Typical EMC Deviation | +
0.03 pH; +0.30C;+2 mV |
| pH Calibration | Automatic
1 or 2 points with 5 memorize buffer. | | Temperature Compensation | Automatic
from 0 to 1000C | | Electrode | HI
1131B | | Temperature
probe | HI7669/2W
with 1 m cable. | | Power
supply | 12VDC | | Dimensions | 240
x 182 x 74 mm | | Weight | 1.1
Kg. |
|

|
|
SOM CODE : 1462/209. 
Model :
pH209 COMPANY : HANNA, ITALY.
pH/mV
Bench Meter For School With Electrode. The
pH offset and slope are manually adjustable in order to display
the calibration concept and the electrode characteristic to the
students. Measurement can be performed for pH with manual
temperature compensation as well as for REDOX (Reduction Oxidation
Potential). The selected temperature is displayed to ensure better
accuracy.
The LCD displays the temperature comprehensively while manually
compensating for its effects.
|
|
|
Specifications : | SOM
CODE | 1462/209 | | Model | pH
209 | | Range | pH | 0.00 to
14.0 |
| mV | +1999 |
| Resolution | pH | 0.01 |
| mV | 1 |
| Accuracy | pH | +
0.01 |
| mV | +1 |
| Typical EMC Deviation | +
0.03 pH; +2 mV |
| pH Calibration | Automatic
1 or 2 points through offset and
slope knobs | | Temperature Compensation | Automatic
from 0 to 1000C | | Electrode | HI
1332B | | Temperature
Impedance | 1012
ohm | | Power
supply | 12VDC | | Dimensions | 240
x 182 x 74 mm | | Weight | 1.0
K
g. |
|
Features :
- Simple 2-Button Operation.
- Manual Calibration.
- Long Battery Life. |
|
|
SOM CODE :
1458/68.
Model : 4330.
COMPANY
: JENWAY, ENGLAND.
Conductivity/Ph/mV/Ion/Salinity
Meter With Elect 230V.
Specifications :
| Som
Code |
1458/68 |
| Model |
4330 |
| Ranges |
0
to 1999µS |
| Resolution |
0.001µS
to 0.01S |
| Accuracy |
+
0.5% + 2 digits |
| pH
Range |
-2
to 19.999pH/+1999.9 mV |
| Salinity
Range |
0
to 99 |
| Power |
9V
ac |
| Size/Weight |
275x240x150mm
/1.2 kg |
| Data
Logging |
100
results |
|
|
Features :
-Dual measurement system.
-Menu driven operation.
-Simultaneous readout of pH, conductivity & temperature.
-mV resolution to 0.1
-Individual/combined use of sensors.
-Fully G.L.P compliant.
|
|
SOM CODE :
1462/6.
Model : 3080/3080HL, 3090/3090HL
COMPANY
: JENWAY, ENGLAND.
pH METER
The industrial range of
electrochemical instrument are supplied in either DIN standard sized
steel panel mounting cases. Or wall mounted water resistant cases.
All of these units will measure pH over the range of 0 to 14pH with a
switchable resolution of 0.1pH to 0.01pH.
The pH mode is automatically temperature compensated over the range of 0
to 1000C. A millivolt mode is also provided for the
measurement of Redox potentials.
Specifications :
| Som
Code |
1462/6 |
| Model |
3080/3090 |
| Ranges |
0
to 14.0 pH
0 to 14.00 pH
0 to + 1999 mV |
| Resolution |
0.1pH
0.01pH
1 mV |
| Accuracy |
+
0.1 pH
+
0.2 pH
+
1mV |
| Display |
12.5
mm LED |
| Power |
110/240V
AC, 50/60Hz. |
| Size/Weight |
3080 |
96x96x150mm
/1.1 kg |
| 3090 |
225x220x125mm
/ 2 kg |
|
|
|
SOM CODE : 1462/110  Model : HI9025C COMPANY : HANNA, ITALY.
pH/mV/DC Meter Waterproof Micro 0.00 To 14.00 pH .
HI 9025
microprocessor-based pH meters in waterproof casings. HI 9025 measures pH,
ion concentration and ORP in the mV range.
Features : - Ready functions. - Rugged, Waterproof Construction's - Dual level display with Graphic symbol.
|
|

|
Specifications : | SOM
CODE | 1462/110 | | Model | HI 9025C | | Range pH | 0.00 to 14.00 | | Resolution pH | 0.01 | | Accuracy | + 0.01 | | Typical EMC | + 0.01 | Temperature Compensation | Automatic or Manual from 0 to 1000C | | Dimensions | 196 x 80 x 60 mm | | Weight | 425 g. |
|
|
|
SOM CODE : 1462/23  Model :
HI9210N COMPANY : HANNA, ITALY.
pH
Meter With Electrode waterproof Portable. The
HI 9210N is heavy-duty pH meter is designed to provide
laboratory result and accuracy under harsh industrial conditions.
The unit can be calibrated at any pH buffer value. |
Specifications :
| SOM
CODE | 1462/23 | | Model | HI
9210N | | Range | pH | 0.00 to
14.0 pH |
| Temperature | 0.0
to 70.00C |
| Resolution | pH | 0.01 |
| Temperature | 0.10C |
| Accuracy | pH | +
0.02 |
| Temperature | +0.50C |
Typical EMC
Deviation | pH | +
0.02 |
| Temperature | +0.50C |
| pH Calibration | Manual 2
points through trimmers. | | Temperature Compensation | Automatic
from 0 to 700C | | Electrode | HI
1217D | | Battery
Type/Life | 4x1.5V
AA/ 2000 hours | | Dimensions | 196
x 80 x 60 mm | | Weight | 320
g. |
|

|
|
|
SOM CODE : 1462/31.  Model :
HI991301N. COMPANY : HANNA, ITALY.
pH/EC/TDS/DC Meter
With Water Proof Case & Electrode.
Features
:
- 4 instruments in one : pH, conductivity, TDS and
temperature all in one meter with a single probe.
- Tailor made for your application : Customized pH/EC
calibration, select EC/TDS conversion factor and temperature
coefficient and choose the temperature scale that best fits
your application.
- Easy of use, accuracy and durability : Two button
operation, microprocessor based, rugged instrument and probe.
|
|

|
Specifications :
| SOM
CODE | 1462/31 | | Model | HI
991301N | | Range | 0.00
to 14.00 pH; 0.0 to 60.00C;
0.00 to 19.99 mS/cm (EC); 0.00 to 10.00 pt. (TDS) | | Resolution | 0.01pH;
0.10C; 0.01mS/cm; 0.01 pt. | | Accuracy | + 0.01pH;
+ 0.50C; + 2% Full Scale (EC/TDS) | | Typical EMC
Deviation | +
0.3 pH; + 10C; + 2% Full Scale
(EC/TDS) | Temperature Compensation | pH
: Automatic from 0 to 600C | | Probe | HI
1288 pH/EC/TDS probe with built-in
temperature sensor | | Battery
Life/Type | 500
hours approx. continuous use/4 x 1.5V AAA | | Dimensions | 143
x 80 x 38 mm | | Weight | 320
g. |
|
|
|
SOM CODE : 1462/314 Model : HI8314. COMPANY : HANNA, ITALY.
pH/mV/DC Meter With Electrode ATC 0.00 to 14.00
pH. HI 8314
is a portable, hand-held multipurpose meter that combines accurate measurement of pH/mV/0C and ATC with a membrane keypad.
Specifications :| SOM
CODE | 1462/314 | | Model | HI 8314 | | Range | 0.00 to 14.0 pH 0 to + 1999 mV 0.0 to 1000C | | Resolution | 0.01 pH 1 mV 0.1 0C | | Accuracy | +0.01pH | | Typical EMC | +0.05 pH | | Dimensions | 185 x 82 x 45 mm | | Weight | 570 g. |
|
|
Features : -High Accuracy. -ATC -Easy Operation. -Accurate Thermometer.
|
|
SOM CODE : 1462/1 Model : HI8014 COMPANY : HANNA, ITALY.
pH/mV/DC Meter W/Electrode 0.00/14.00 pH
Battery. HI 8014 affordable with Calibration at any Buffer - Ideally for education field. Measurements can be performed by the pH and REDOX( reduction/oxidation potential) with manual temperature compensation.
Specifications : | SOM
CODE | 1462/1 | | Model | HI 8014 | | Range pH | 0.00 to 14.00 | | Resolution pH | 0.01 | | Accuracy | + 0.01 | | Typical EMC | + 0.05 | Temperature Compensation | Manual from 0 to 105% | | Dimensions | 185 x 82 x 45 mm | | Weight | 520 g. |
|

|
Features :
- Easy-to-operate. - Manual Calibration. - Manual Temperature Compensation. |
|
|
SOM CODE : 1462/128  Model : HI 98128 COMPANY : HANNA, Italy.
The Latest Invention In Ph Meter( pHep4 & pHep5).
The pHep4 and pHep5 include features such as : 1) Dual-level LCD. 2) Battery level indicator. 3) Replaceable pH electrode cartridge. 4) Stability Indicator. 5) Automatic shut-off. 6) Automatic Calibration. 7) Waterproof casing plus 100% buoyancy.
| 
|
|
SOM CODE : 1462/2  Model :
HI98107 COMPANY : HANNA, ITALY.
pH
Tester Pocket 0.0 to 14.o pH Battery Power. The
standard in pH measurement has been improved with a more rugged
ergonomic casing, larger LCD, extractable pcb, replaceable junction,
replaceable electrode.
Specifications : | SOM
CODE | 1462/2 | | Model | HI
98107 | | Range pH | 0.0 to
14.0 | | Resolution pH | 0.1 | | Accuracy | +
0.1 | | Typical EMC | +
0.1 | | Calibration | Manual
1 or 2 points. | Temperature Compensation | NA | | Dimensions | 175
x 41 x 23 mm | | Weight | 78
g. |
|

|
|
|
SOM CODE : 1462/114, 1462/115 Model : HI98114, HI98115 COMPANY : HANNA, ITALY.
pH/TDS Meter W/ Probe 0/1990 µS/CM Watercheck. Watercheck
is a combination pocket meter providing on-the-spot measurements of pH and conductivity of TDS.
Specifications : | SOM
CODE | 1462/114 | 1462/115 | | Model | HI 98114( Watercheck ) | HI 98115 ( Watercheck1 ) | | Range pH | 0.00 to 14.00 0 TO 1990 µS/cm | 0.00 to 14.00 0 to 1990 ppm (mg/L) | | TDS Ratio | ----- | 0.5 ppm = 1 µS/cm | | Resolution pH | 0.1pH 10 µS/cm | 0.1pH 10 ppm | | Accuracy | + 0.2 pH | + 0.2 pH | | Typical EMC | + 0.2 pH | + 0.2 pH | Temperature Compensation | Automatic with a
ß of 2% per degree 0C | Automatic with a
ß of 2% per degree 0C | | Dimensions | 194 x 29 x 15mm | 194 x 29 x 15mm | Conductivity/TDS Calibration. | Single Point. | Single Point. | | Weight | 70 g. | 70 g. |
|

|
Features : - 2 meters in 1. - Long battery Life. - FRP : Fast Response Probe. |
|
SOM CODE :
N84/14  Model :
HI70300L COMPANY : HANNA, Italy.
Storage
Solution For pH/ORP Electrode 460 ml/Bottle.
This solution are
prepared with high grade Potassium Chloride and Potassium
Hydrogen Phthalate by titration with NIST 2201 standardized Silver Nitrate
and
NIST 84j standardized Sodium Hydroxide Solution, respectively.
|
|
|
SOM CODE : 1462/14, 1462/17 Model : HI98151, HI98153. COMPANY : HANNA, ITALY.
pH Tester Standard Waterproof 0.0 to 14.0 pH. The new waterproof housings of the pHep® waterproof testers provide complete protection in outdoor applications, harsh industrial
environments as well as accidental spills. These testers are ideal for swimming pools, fish farming, electroplating industry, printing, agriculture, waste water processing and many other application where humidity and condensation would render litmus paper useless or ruin circuitry of ordinary meters.
Specifications : | SOM
CODE |
1462/14 |
1462/17 | | Model | HI 98151 | HI 98153 | | Range pH | 0.0 to 14.0 | 0.00 to 14.00 | | Resolution pH | 0.1 | 0.1 | | Accuracy | + 0.1 pH | + 0.1 pH | | Typical EMC | + 0.1 pH | + 0.1 pH | Temperature Compensation | NA | Automatic 0 to 500C | | Dimensions | 150 x 30 x 24 mm | 150 x 30 x 24 mm | Conductivity/TDS Calibration. | Manual 1 or 2 points | Automatic 1 or 2 points | | Weight | 85 g. | 85 g. |
| 
|
Features : -Completely waterproof. -Easy-to-read LCD -Positive push button 'ON/OFF' switch. -300 hour of battery life. -Automatic Temperature Compensation. -HI 98153 is microprocessor based with error and self-diagnostic message.
|
|
SOM CODE : 1462/15 Model : HI98103. COMPANY : HANNA, ITALY.
pH Tester LCD 0.00 - 14.00 pH/0.01pH with Electrode. At
the cost of a few rolls of pH litmus paper, you can have the industry's latest electronic pH tester.
checker ® supplies you with the fast and accurate readings on a large LCD.
Specifications : | SOM
CODE | 1462/15 | | Model | HI 98103 | | Range pH | 0.00 to 14.00 | | Resolution pH | 0.01 | | Accuracy | + 0.2 | | Typical EMC | + 0.1 | | Calibration | Manual 2 points through trimmers. | | Dimensions | 66 x 50 x 25 mm | | Weight | 70 g. |
|

|
Features : -Large and easy to read LCD. -High accuracy with 0.01 resolution. -Two point fast and accurate calibration. -Usable with virtually and pH electrode. |
|
SOM CODE : 1462/12 Model : PICCOLO+. COMPANY : HANNA, ITALY.
pH Meter & Thermometer 1-13 pH/0-70 DC LCD ATC. PICCOLO is a revolutionary pH-meter with a 4-in-1 "Electrode + Amplifier" design. Conventional pH-meters are susceptible to the weak high impedance signal which makes the electrode, connector, cable and meter delicate and vulnerable to noise, humidity and dirty environment.
PICCOLO has overcome this problems with a preamplifier electrode delivering a strong signal to the meter. The 4-in-1 interchangeable electrode is inexpensive and rugged and houses the pH sensor, reference system, temperature sensor and the amplifier module.
Specifications :| SOM
CODE | 1462/12 | | Model | PICCOLO+ | | Range | 1.00 to 13.0 pH 0.0 to 70.0 0C | | Resolution | 0.01 pH 0.1 0C | | Accuracy | +0.01pH/ +10C | | Typical EMC | +0.2 pH/+10C | | Dimensions | 265 x 29 x 15 mm | | Weight | 400 g. |
|

|
Features : -Accuracy. -Easy to use. -Replaceable Electrode. -Automatic Temperature Compensation. -Temperature Read-out.
|
|
SOM CODE : 1462/124 
Model : HI1131B
COMPANY : HANNA, ITALY.
pH
Electrode Combination BNC General Purpose.
Combination pH Electrode :
| Junction |
Shape |
Plug |
Pressure
Bar/PSI |
Cable |
Temp.
Range0C |
Body |
| A |
SE |
B |
0.5/7.25 |
Coaxial |
-5/+100 |
glass |
|
|
|
SOM CODE : 1462/53 
Model : HI1053B COMPANY : HANNA, ITALY.
pH
Electrode Combination BNC Emulsion.
Combination pH Electrode :
| Junction |
Shape |
Plug |
Pressure
Bar/PSI |
Cable |
Temp.
Range0C |
Body |
| B |
CB |
B |
0.5/7.25 |
Coaxial |
-5/+100 |
glass |
|

|
|
SOM CODE : 1462/123 Model : HI1230B COMPANY : HANNA, ITALY.
pH Combination Electrode BNC Plug 1Mtr Dia 3mm. pH combination electrode with BNC plug and a cable of 1 meter.
|

|
|
SOM CODE : 1462/332  Model :
HI1332B COMPANY : HANNA, ITALY.
pH
Meter Sensor.
Combination pH Electrodes
| Model |
Junction |
Shape |
Plug |
Pressure
Bar/PSI |
Cable |
Temp
Range 0C |
| HI1332B |
A |
SC |
B |
0.5/7.25 |
Coaxial |
0/+80 |
|

Model : HI1332B
|
|
|

Model : HI931700
|
SOM CODE : 1462/93  Model :
HI931700+HI1002/3 COMPANY : HANNA, ITALY.
pH
Controller 220V/240V With pH Electrode & Mounting Bracket. -
HI931700
is the smallest panel mounted pH controller around.
- Its small size allows installation close to the monitored
equipment, thus adding to its
versatility in the industry.
- Possible application are almost infinite; from textile
(particularly in the monitoring of pH
in the wool processing), paper, photographic, planting and
aquarium to the process
industry. Also small swimming pools and water purification
plants can be
controlled with HI931700.
- HI931700 is equipped with single set point with
selection of acid or alkaline dosage. It
accept direct input from any combination pH electrode
ending in a BNC connector and
provides measurements from 0 to 14 pH with a resolution of
0.01 pH.
Combination pH Electrodes for high pressure
application - HI1002/3
| Model |
Junction |
Max.Pressure |
Cable |
Temp
Range 0C |
| HI1002/3 |
double |
6
bar |
3
m |
-5
to 800C |
|
|

Model : HI1002/3
|
|
|
SOM CODE : 1462/404  Model :
HI76404 COMPANY : HANNA, ITALY.
ELECTRODE
HOLDER.
Cantilever stand
with a large steel base provides greater stability and flexibility and
holds up to 3 electrodes in any position. The base is enamel coated for
lasting protection against spills. It is also constructed in heavy steel,
making the holder very sturdy and virtually impossible to tip over
accidentally.
|
|
|
SOM CODE : 1462/122  Model :
HI7669/2N COMPANY : HANNA, ITALY.
TEMPERATURE
PROBE FOR pH METER.
|
|
|
SOM CODE : 1462/767  Model :
HI766E1 COMPANY : HANNA, ITALY.
PROBE
FOR GENERAL PURPOSE.
|
|
|
SOM CODE : 1462/86 Model :
HI7686 COMPANY : HANNA, ITALY.
CONDUCTIVITY
PROBE.
|
|
|
Process Instrumentation/ACCESSORIES 
Company : HANNA, ITALY.
| SOM
CODE |
MODEL |
DESCRIPTION |
| D1/52 |
HI721101 |
KIT
PUMPHEAD FOR BL PUMP |
| D1/53 |
HI720030 |
LPDE
HOSE 10 MT. |
| D1/54 |
HI721101 |
KIT
DISCHARGE VALVE ASSEMBLY |
| D1/55 |
HI721103 |
KIT
SUCTION VALVE ASSEMBLY |
| D1/56 |
HI721003 |
KIT
10 GLASS BALL & 10 O-RING |
| D1/57 |
HI720 |
INJECTION
VALVE ASSEMBLY |
|
|
Buffer Solution
Made In : SPAIN.
| SOM
CODE |
MODEL |
DESCRIPTION |
| N84/23 |
SO10071000 |
Buffer
solution pH=7 /1 Ltr per bottle |
| N84/25 |
SO10091000 |
Buffer
solution pH=9 /1 Ltr per bottle |
| N84/27 |
SO10101000 |
Buffer
solution pH=10/1 Ltr per bottle |
| N84/28 |
SO20040500 |
Buffer
solution pH=4 Red colored 500mL per bottle |
Note : Please mention the product "SOM CODE" while making request.
|
|
Copyright © Saudi (Overseas) Marketing And Trading Company